Agilent E4428C ESG Analog Signal Generator (Pre-Owned)Agilent E4428C ESG Analog Signal Generator (Pre Owned) Key Features At A Glance Frequency coverage to 6 GHz across the option range (Option 503 to 3 GHz; Option 506 to 6 GHz) AM, FM, phase, and pulse modulation with composite and simultaneous modulation paths Built in function generator: sine, square, ramp, triangle, pulse, and noise waveforms GPIB (IEEE 488. 2), RS 232, and LAN (10BaseT) remote interfaces with SCPI for automation Step and list sweep
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Agilent E4428C ESG Analog Signal Generator (Pre-Owned)

Key Features At A Glance

  • Frequency coverage to 6 GHz across the option range (Option 503 to 3 GHz; Option 506 to 6 GHz)
  • AM, FM, phase, and pulse modulation with composite and simultaneous modulation paths
  • Built-in function generator: sine, square, ramp, triangle, pulse, and noise waveforms
  • GPIB (IEEE-488.2), RS-232, and LAN (10BaseT) remote interfaces with SCPI for automation
  • Step and list sweep of both frequency and power, 2 to 65,535 points
  • 0.01 Hz frequency resolution and 0.02 dB level resolution
  • High-stability timebase, aging rate < ±0.1 ppm/yr; 2-year calibration cycle
  • Lightweight (< 16 kg), rack-mountable; 50 Ω type-N RF output

The Agilent E4428C ESG is an analog signal generator that produces RF carrier signals with analog modulation across a frequency range that extends to 6 GHz in its widest configuration. It delivers calibrated output power, a high-stability frequency reference, and a built-in modulation source, presenting frequency, power, and modulation control through both a front panel and full remote programming. The instrument is offered in frequency-range and output-power configurations selected by option, with a 50 Ω type-N RF output.

An analog signal generator provides a known, controllable RF stimulus — a carrier at a defined frequency and amplitude that can be modulated in a defined way — so that a device or system can be excited and its response measured. The E4428C generates amplitude, frequency, phase, and pulse modulation, and its spectral-purity and jitter performance is characterized at SONET/SDH carrier frequencies and data rates of 155, 622, and 2488 MB/s. Step and list sweeps of both frequency and power allow a sequence of carrier settings to be stepped through automatically.

ValueTronics stocks and holds its own test-and-measurement inventory in a 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every used unit is inspected and functionally verified in-house before it ships, while new units leave factory-sealed exactly as received. Holding inventory directly lets us match the right instrument and configuration to an engineer's application and get it out the door quickly.

Brand Heritage

This instrument carries Agilent Technologies branding. Agilent originated as the test-and-measurement business of Hewlett-Packard, which was spun out as Agilent Technologies in 1999; that electronic measurement business was subsequently established as Keysight Technologies in 2014.

Accessories Supplied

  • CD-ROM of English user guide and assembly level service manual (E4428C-CD1, standard with instrument)
Newer model: per the manufacturer, this unit has been replaced by MXG X-Series.

Product Core & Specifications

Specification Value
Frequency
Frequency range (Option 503) 250 kHz to 3 GHz [electronic attenuator standard]
Frequency range (Option 506) 250 kHz to 6 GHz [mechanical attenuator only]
Frequency minimum 100 kHz (performance below 250 kHz not guaranteed)
Frequency resolution 0.01 Hz
Frequency switching speed, Option 503 [hops < 5 MHz within a band] Freq. (< 9 ms); Freq./Amp. (< 9 ms)
Frequency switching speed, Option 506 [hops < 5 MHz within a band] Freq. (< 16 ms); Freq./Amp. (< 17 ms); within a band (< 12 ms) / (< 14 ms)
Phase offset Adjustable remotely [LAN, GPIB, RS-232] or via front panel in nominal 0.1 ° increments
Sweep modes
Operating modes Frequency step, amplitude step and arbitrary list
Dwell time 1 ms to 60 s
Number of points 2 to 65,535 (Step); 2 to 1601 (List)
Internal Reference Oscillator
Aging rate < ±0.1 ppm/yr or < ±0.0005 ppm/day after 45 days
Temp [0 to 55 °C] (< ±0.05 ppm)
Line voltage (< ±0.002 ppm)
Line voltage range (+5% to –10%)
RF reference input frequency 1, 2, 5, 10 MHz ±0.2 ppm
RF reference output frequency 10 MHz
RF reference output amplitude 4 dBm ±2 dB
Output Power — Maximum Available Power (measured)
250 kHz to 250 MHz Opt 503: +11 to –136 dBm; Opt 503 with UNB: +15 to –136 dBm; Opt 506: +12 to –136 dBm
> 250 MHz to 1 GHz Opt 503: +13 to –136 dBm; Opt 503 with UNB: +17 to –136 dBm; Opt 506: +14 to –136 dBm
> 1 to 3 GHz Opt 503: +10 to –136 dBm; Opt 503 with UNB: +16 to –136 dBm; Opt 506: +13 to –136 dBm
> 3 to 6 GHz Opt 503: N/A; Opt 503 with UNB: N/A; Opt 506: +10 to –136 dBm
Level resolution 0.02 dB
Level range with Attenuator Hold active, 250 kHz to 1 GHz Opt 503: 23 dB; Opt 503 with UNB: 27 dB; Opt 506: 24 dB
Level range with Attenuator Hold active, > 1 to 3 GHz Opt 503: 20 dB; Opt 503 with UNB: 26 dB; Opt 506: 23 dB
Level range with Attenuator Hold active, > 3 to 6 GHz Opt 503: N/A; Opt 503 with UNB: N/A; Opt 506: 20 dB
Level Accuracy [dB], Option 503 (23 °C ±5 °C)
250 kHz to 2.0 GHz +7 to –50 dBm: ±0.5; –50 to –110 dBm: ±0.5; –110 to –127 dBm: ±0.7; < –127 dBm: (±1.5)
2.0 to 3 GHz +7 to –50 dBm: ±0.6; –50 to –110 dBm: ±0.6; –110 to –127 dBm: ±0.8; < –127 dBm: (±2.5)
Level Accuracy [dB], Option UNB (23 °C ±5 °C)
250 kHz to 2.0 GHz +10 to –50 dBm: ±0.5; –50 to –110 dBm: ±0.7; –110 to –127 dBm: ±0.8; < –127 dBm: (±1.5)
2.0 to 3 GHz +10 to –50 dBm: ±0.6; –50 to –110 dBm: ±0.8; –110 to –127 dBm: ±1.0; < –127 dBm: (±2.5)
Level Accuracy [dB], Option 506 (23 °C ±5 °C)
250 kHz to 2.0 GHz +7 to –50 dBm: ±0.6; –50 to –110 dBm: ±0.8; –110 to –127 dBm: ±0.8; < –127 dBm: (±1.5)
2.0 to 3 GHz +7 to –50 dBm: ±0.6; –50 to –110 dBm: ±0.8; –110 to –127 dBm: ±1.0; < –127 dBm: (±2.5)
3 to 4 GHz +7 to –50 dBm: ±0.8; –50 to –110 dBm: ±0.9; –110 to –127 dBm: ±1.5; < –127 dBm: (±2.5)
4 to 6 GHz +7 to –50 dBm: ±0.8; –50 to –110 dBm: ±0.9; –110 to –127 dBm: (±1.5)
Level accuracy with ALC off (±0.15 dB) [relative to ALC on, after power search is executed]
Level switching speed, Normal operation [ALC on] Opt 503: (< 15 ms); Opt 503 with UNB: (< 21 ms); Opt 506: (< 21 ms)
Level switching speed, power search manual Opt 503: (< 83 ms); Opt 503 with UNB: (< 95 ms); Opt 506: (< 95 ms)
Level switching speed, power search auto Opt 503: (< 103 ms); Opt 503 with UNB: (< 119 ms); Opt 506: (< 119 ms)
Spectral Purity
SSB phase noise [at 20 kHz offset], 500 MHz < –135 dBc/Hz, (< –138 dBc/Hz)
SSB phase noise [at 20 kHz offset], 1 GHz < –130 dBc/Hz, (< –134 dBc/Hz)
SSB phase noise [at 20 kHz offset], 2 GHz < –124 dBc/Hz, (< –128 dBc/Hz)
SSB phase noise [at 20 kHz offset], 3 GHz < –121 dBc/Hz, (< –125 dBc/Hz)
SSB phase noise [at 20 kHz offset], 4 GHz < –118 dBc/Hz, (< –122 dBc/Hz)
SSB phase noise [at 20 kHz offset], 6 GHz < –113 dBc/Hz, (< –117 dBc/Hz)
Residual FM [CW mode, 0.3 to 3 kHz BW, CCITT, rms] < N x 1 Hz (< N x 0.5 Hz)
Harmonics < –30 dBc above 1 GHz, (< –30 dBc 1 GHz and below)
Nonharmonics, 250 kHz to 250 MHz > 3 kHz offset: < –65 dBc; > 10 kHz offset: (< –58 dBc)
Nonharmonics, 250 MHz to 500 MHz < –80 dBc; < –80 dBc
Nonharmonics, 500 MHz to 1 GHz < –80 dBc; < –80 dBc
Nonharmonics, 1 to 2 GHz < –74 dBc; < –74 dBc
Nonharmonics, 2 to 4 GHz < –68 dBc; < –68 dBc
Nonharmonics, 4 to 6 GHz < –62 dBc; < –62 dBc
Subharmonics ≤ 1 GHz None
Subharmonics > 1 GHz None
Frequency Modulation (FM)
Maximum deviation N x 1 MHz
Resolution 0.1% of deviation or 1 Hz, whichever is greater
Modulation frequency rate [deviation = 100 kHz], FM path 1 [DC] 1 dB BW: DC to 100 kHz; 3 dB BW: (DC to 10 MHz)
Modulation frequency rate, FM path 2 [DC] 1 dB BW: DC to 100 kHz; 3 dB BW: (DC to 0.9 MHz)
Modulation frequency rate, FM path 1 [AC] 1 dB BW: 20 Hz to 100 kHz; 3 dB BW: (5 Hz to 10 MHz)
Modulation frequency rate, FM path 2 [AC] 1 dB BW: 20 Hz to 100 kHz; 3 dB BW: (5 Hz to 0.9 MHz)
Deviation accuracy [1 kHz rate, deviation < N x 100 kHz] < ± 3.5% of FM deviation + 20 Hz
Carrier frequency accuracy relative to CW in DCFM ±0.1% of set deviation + (N x 1 Hz)
Distortion [1 kHz rate, dev. = N x 100 kHz] < 1%
FM external inputs sensitivity 1 Vpeak for indicated deviation
FM external inputs impedance 50 Ω, nominal
Phase Modulation (ØM)
Resolution 0.1% of set deviation
Modulation frequency response, Normal BW Max deviation N x 10 radians; ØM path 1: DC to 100 kHz; ØM path 2: DC to 100 kHz
Modulation frequency response, High BW Max deviation N x 1 radians; ØM path 1: (DC to 1 MHz); ØM path 2: (DC to 0.9 MHz)
Deviation accuracy [1 kHz rate, Normal BW mode] < ±5% of deviation + 0.01 radians
Distortion [1 kHz rate, deviation < 10N radians, Normal BW mode] < 1%
ØM external inputs sensitivity 1 Vpeak for indicated deviation
ØM external inputs impedance 50 Ω, nominal
Amplitude Modulation (AM) [fc > 500 kHz]
Range 0 to 100%
Resolution 0.1%
Rates [3 dB bandwidth], DC coupled 0 to 10 kHz
Important: Option 506 and Option UNB cannot be ordered together: Option 506 is standard with the high-power mechanical attenuator used in Option UNB.
Important: Frequency performance below 250 kHz is not guaranteed (frequency minimum 100 kHz).
Important: Power requirements: 90 to 254 V; 50 or 60 Hz; 300 W maximum, power factor corrected. Not for 400 Hz use. For 400 Hz systems, order transformer 70001-60066.
Important: Save and recall of user files and instrument states from non-volatile storage is guaranteed only over the range 0 to 40 °C.
Important: External 1 and External 2 modulation input damage levels are 5 Vrms and 10 Vpeak (50 ohm input impedance).
Important: Reverse power protection maximum DC voltage is 40 V.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Agilent E4428C ESG Analog Signal Generator (Pre-Owned)

Item no : 1127455638
sold recently : Login >>
US$ 1527.97
Pay in 4 interest-free payments of $381.99 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 21 - Jun 26

Enjoy 20% off shipping

US$ 1527.97

1-11

US$ 1375.17

12-35

US$ 1069.58

36-59

US$ 916.78

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches