The Rohde & Schwarz R&S FPL1000 is a signal and spectrum analyzer offered in two models: the R&S FPL1003, covering 5 kHz to 3 GHz, and the R&S FPL1007, covering 5 kHz to 7.5 GHz. Both models are built on a common platform with a 10.1-inch (21 cm) WXGA color LC TFT display at 1280 x 800 resolution, a 50 ohm N-female RF input, and a frequency resolution of 0.01 Hz.
Beyond core spectrum measurements, the platform can be extended with licensed application packages that the analyzer supports as separately ordered software options. These include an EMI measurement application, a phase noise measurement application, noise figure and gain measurements, AM/FM/PM demodulation, vector signal analysis, BER measurements with PRBS data, and power sensor measurement with R&S NRP-series sensors. Each application is a separate firmware license rather than a base-unit feature, so the measurement set can be tailored to the work at hand.
ValueTronics stocks and holds the R&S FPL1000 in our own 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, keeping inventory on hand so customers work directly with a company that controls its own stock.
Rohde & Schwarz is an independent, privately held company headquartered in Munich, Germany, founded more than 80 years ago. It has operated continuously under the Rohde & Schwarz name, with no major corporate rebranding or acquisition-driven name changes.
The R&S FPL1000 family comprises two signal and spectrum analyzer models built on a shared platform. The R&S FPL1003 covers 5 kHz to 3 GHz, and the R&S FPL1007 extends the upper frequency limit to 7.5 GHz. Both models share the same display, connectivity, RF input, frequency resolution, and option ecosystem.
Because the two models differ primarily in frequency coverage, the choice between them is driven by the highest frequency a given application needs to measure. The comparison table below lists the specifications that distinguish the models.
Each new model below is its own dedicated product page with condition-matched pricing. Select the model whose frequency coverage and installed options fit your application, then review its specifications and availability on that page.
The defining difference across the family is upper frequency limit: the R&S FPL1003 reaches 3 GHz, while the R&S FPL1007 reaches 7.5 GHz. The internal generator option is also model-specific, ordered as R&S FPL1-B9 to match the host analyzer's frequency range.
Aside from frequency coverage, the two models share their core architecture: the same 0.01 Hz frequency resolution, resolution-bandwidth ranges, display, data storage, and interface set. Optional capabilities such as the OCXO reference, RF preamplifier, 40 MHz analysis bandwidth, internal battery, and the licensed measurement applications apply across both models. See the comparison table for the model-by-model specifications.
| Model | Frequency Range | Resolution Bandwidth | SSB Phase Noise (1 GHz, 10 kHz offset) |
|---|---|---|---|
| FPL1007 | 5 kHz to 7.5 GHz | 1 Hz to 10 MHz in 1/2/3/5 sequence | < –105 dBc (1 Hz), –108 dBc (1 Hz) (typ.) |
| FPL1003 | 5 kHz to 3 GHz | 1 Hz to 10 MHz in 1/2/3/5 sequence | < –105 dBc (1 Hz), –108 dBc (1 Hz) (typ.) |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Frequency | |
| Frequency range | 5 kHz to 7.5 GHz |
| Frequency resolution | 0.01 Hz |
| Reference frequency aging per year (standard) | 1 · 10–6 |
| Temperature drift, 0 °C to +50 °C (standard) | 1 · 10–6 |
| Achievable initial calibration accuracy (standard) | 5 · 10–7 |
| Marker resolution | 0.01 Hz |
| Number of sweep (trace) points, default | 1001 |
| Number of sweep (trace) points, range | 101 to 100001 |
| Frequency counter resolution | 1 Hz |
| Display range for frequency axis | 0 Hz, 10 Hz to max. frequency |
| Spectral Purity (SSB Phase Noise, f = 1000 MHz) | |
| Carrier offset 100 Hz | –88 dBc (1 Hz) (nom.) |
| 1 kHz | < –99 dBc (1 Hz) |
| 10 kHz | < –105 dBc (1 Hz), –108 dBc (1 Hz) (typ.) |
| 100 kHz | < –110 dBc (1 Hz), –115 dBc (1 Hz) (typ.) |
| 1 MHz | < –130 dBc (1 Hz), –135 dBc (1 Hz) (typ.) |
| 10 MHz | –152 dBc (1 Hz) (nom.) |
| Sweep Time | |
| Range, span = 0 Hz | 1 µs to 8000 s |
| span ≥ 10 Hz, RBW ≥ 100 kHz | 1 ms to 8000 s |
| span ≥ 10 Hz, RBW < 100 kHz | 75 µs to 8000 s |
| Sweep time accuracy, span = 0 Hz | 0.1 % (nom.) |
| Sweep time accuracy, span ≥ 10 Hz, RBW ≥ 100 kHz | 3 % (nom.) |
| Resolution Bandwidths | |
| Resolution bandwidths (–3 dB), sweep filters | 100 kHz to 10 MHz in 1/2/3/5 sequence |
| FFT filters | 1 Hz to 50 kHz in 1/2/3/5 sequence |
| Bandwidth uncertainty | < 3 % (nom.) |
| Shape factor 60 dB:3 dB | < 5 (nom.) |
| Channel filter bandwidth uncertainty | < 2 % (nom.) |
| Channel filter shape factor 60 dB:3 dB | < 2 (nom.) |
| EMI filters (with R&S®FPL1-K54), bandwidths (–6 dB) | 10/100/200 Hz; 1/9/10/100/120 kHz; 1 MHz |
| Video bandwidths | 1 Hz to 10 MHz in 1/2/3/5 sequence |
| Signal analysis bandwidth (equalized), standard | 10 MHz (nom.) |
| Signal analysis bandwidth (equalized), with R&S®FPL1-B40 | 40 MHz (nom.) |
| Level | |
| Display range | displayed noise floor up to +30 dBm |
| Maximum input level, DC voltage | 50 V |
| Maximum CW RF power, RF attenuation 0 dB, preamplifier off | 20 dBm (= 0.1 W) |
| Maximum CW RF power, RF attenuation ≥ 10 dB, preamplifier off | 30 dBm (= 1 W) |
| Maximum pulse voltage, RF attenuation ≥ 10 dB | 150 V |
| Maximum pulse energy, RF attenuation ≥ 10 dB, 10 µs | 1 mWs |
| 1 dB compression of input mixer (two tone) | +7 dBm (nom.) |
| TOI, 10 MHz ≤ fin < 300 MHz | > 13 dBm, 16 dBm (typ.) |
| TOI, 300 MHz ≤ fin < 3 GHz | > 17 dBm, 20 dBm (typ.) |
| TOI, 3 GHz ≤ fin ≤ 7.5 GHz | > 15 dBm, 18 dBm (typ.) |
| DANL (RF preamplifier off), 5 kHz ≤ f < 100 kHz | –143 dBm (typ.) |
| 100 kHz ≤ f < 5 MHz | < –140 dBm, –143 dBm (typ.) |
| 5 MHz ≤ f < 3 GHz | < –149 dBm, –152 dBm (typ.) |
| 3 GHz ≤ f < 5 GHz | < –143 dBm, –146 dBm (typ.) |
| 5 GHz ≤ f ≤ 7.5 GHz | < –140 dBm, –143 dBm (typ.) |
| Number of traces | 6 |
| Trace detector | max. peak, min. peak, auto peak (normal), sample, RMS, average |
| Units of level axis | dBm, dBµV, dBmV, dBµA, dBpW, V, A, W |
| Absolute level uncertainty at 50 MHz, +20 °C to +30 °C | < 0.3 dB (σ = 0.1 dB) |
| Total measurement uncertainty, 1 MHz ≤ f < 3 GHz | 0.5 dB |
| Total measurement uncertainty, 3 GHz ≤ f < 7.5 GHz | 0.8 dB |
| Measurement Speed | |
| Local measurement and display update rate | 1 ms (1000/s) (nom.) |
| Maximum sweep rate, remote operation | 0.9 ms (1100/s) (nom.) |
| Remote measurement and LAN transfer | 3.2 ms (357/s) (nom.) |
| Marker peak search | 1.9 ms (nom.) |
| Trigger Functions | |
| Trigger source | free run, video, external, IF power, I/Q power |
| Trigger offset, span ≥ 10 Hz | 0 s to 20 s |
| IF power trigger sensitivity, min. signal power | –60 dBm + RF attenuation – RF preamplifier gain |
| IF power trigger sensitivity, max. signal power | –15 dBm + RF attenuation – RF preamplifier gain |
| Gate length | 10 ns to 20 s, min. resolution 10 ns |
| I/Q Data | |
| Interface | GPIB or LAN interface |
| Memory length | max. 25 Msample I and Q |
| Word length of I/Q samples | 14 bit |
| Sampling rate, standard | 100 Hz to 16 MHz |
| Sampling rate, with R&S®FPL1-B40 | 100 Hz to 100 MHz |
| Maximum signal analysis bandwidth (equalized), standard | 12.8 MHz |
| Maximum signal analysis bandwidth (equalized), with R&S®FPL1-B40 | 40 MHz |
| Inputs and Outputs | |
| RF input impedance | 50 Ω |
| RF input connector | N female |
| VSWR (RF attenuation ≥ 10 dB), 10 MHz ≤ f < 3 GHz | < 1.5 (nom.) |
| VSWR, 3 GHz ≤ f < 7.5 GHz | < 2 (nom.) |
| Setting range of attenuator, standard | 0 dB to 45 dB, in 5 dB steps |
| USB interface | 4 ports, type A plug, version 2.0 |
| Reference output connector | BNC female |
| Reference input frequency range | 10 MHz ± 5 ppm |
| External trigger/gate input | BNC female, 0.5 V to 3.5 V, 10 kΩ |
Important: Maximum input levels: 50 V DC; 30 dBm (1 W) CW RF power at RF attenuation >= 10 dB, or 20 dBm (0.1 W) at 0 dB RF attenuation.
Important: Internal lithium-ion battery packs (R&S®FPL1-B31 / R&S®FPL1-Z4) should be stored in an environment with low humidity, free from corrosive gas, at a recommended temperature range below +21 °C. Extended exposure to temperatures above +45 °C could degrade battery performance and life.
Recommended pairing: the optional noise figure and gain measurement application (R&S FPL1-K30) works with the R&S FS-SNS18 or FS-SNS26 smart noise sources listed among the recommended extras.
This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Ships within 48 hours · Estimated delivery Jun 26 - Jul 1
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order