Rohde & Schwarz FPL1007 7.5 GHz Signal and Spectrum AnalyzerRohde & Schwarz FPL1007 7. 5 GHz Signal and Spectrum Analyzer Key Features At A Glance Two frequency tiers: 5 kHz to 3 GHz (FPL1003) or 5 kHz to 7. 5 GHz (FPL1007) 0. 01 Hz frequency resolution across the series 10. 1" (21 cm) WXGA color LC TFT display, 1280 x 800 resolution LAN 10 100 1000BASE T and four USB 2. 0 ports standard; GPIB (IEEE 488. 2) optional Signal analysis bandwidth 10 MHz standard, 40 MHz with optional R&S FPL1 B40 DANL down to 163
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Rohde & Schwarz FPL1007 7.5 GHz Signal and Spectrum Analyzer

Key Features At A Glance

  • Two frequency tiers: 5 kHz to 3 GHz (FPL1003) or 5 kHz to 7.5 GHz (FPL1007)
  • 0.01 Hz frequency resolution across the series
  • 10.1" (21 cm) WXGA color LC TFT display, 1280 x 800 resolution
  • LAN 10/100/1000BASE-T and four USB 2.0 ports standard; GPIB (IEEE 488.2) optional
  • Signal analysis bandwidth 10 MHz standard, 40 MHz with optional R&S FPL1-B40
  • DANL down to -163 dBm typ. with optional RF preamplifier (frequency-band dependent)
  • Optional internal generator, OCXO reference, and internal lithium-ion battery for portable use
  • Optional licensed applications: EMI, phase noise, noise figure, AM/FM/PM demod, vector signal analysis

The Rohde & Schwarz R&S FPL1000 is a signal and spectrum analyzer offered in two models: the R&S FPL1003, covering 5 kHz to 3 GHz, and the R&S FPL1007, covering 5 kHz to 7.5 GHz. Both models are built on a common platform with a 10.1-inch (21 cm) WXGA color LC TFT display at 1280 x 800 resolution, a 50 ohm N-female RF input, and a frequency resolution of 0.01 Hz.

Beyond core spectrum measurements, the platform can be extended with licensed application packages that the analyzer supports as separately ordered software options. These include an EMI measurement application, a phase noise measurement application, noise figure and gain measurements, AM/FM/PM demodulation, vector signal analysis, BER measurements with PRBS data, and power sensor measurement with R&S NRP-series sensors. Each application is a separate firmware license rather than a base-unit feature, so the measurement set can be tailored to the work at hand.

ValueTronics stocks and holds the R&S FPL1000 in our own 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, keeping inventory on hand so customers work directly with a company that controls its own stock.

Brand Heritage

Rohde & Schwarz is an independent, privately held company headquartered in Munich, Germany, founded more than 80 years ago. It has operated continuously under the Rohde & Schwarz name, with no major corporate rebranding or acquisition-driven name changes.

Compare Other Models in This Series

The R&S FPL1000 family comprises two signal and spectrum analyzer models built on a shared platform. The R&S FPL1003 covers 5 kHz to 3 GHz, and the R&S FPL1007 extends the upper frequency limit to 7.5 GHz. Both models share the same display, connectivity, RF input, frequency resolution, and option ecosystem.

Because the two models differ primarily in frequency coverage, the choice between them is driven by the highest frequency a given application needs to measure. The comparison table below lists the specifications that distinguish the models.

Each new model below is its own dedicated product page with condition-matched pricing. Select the model whose frequency coverage and installed options fit your application, then review its specifications and availability on that page.

The defining difference across the family is upper frequency limit: the R&S FPL1003 reaches 3 GHz, while the R&S FPL1007 reaches 7.5 GHz. The internal generator option is also model-specific, ordered as R&S FPL1-B9 to match the host analyzer's frequency range.

Aside from frequency coverage, the two models share their core architecture: the same 0.01 Hz frequency resolution, resolution-bandwidth ranges, display, data storage, and interface set. Optional capabilities such as the OCXO reference, RF preamplifier, 40 MHz analysis bandwidth, internal battery, and the licensed measurement applications apply across both models. See the comparison table for the model-by-model specifications.

Model Frequency Range Resolution Bandwidth SSB Phase Noise (1 GHz, 10 kHz offset)
FPL1007 5 kHz to 7.5 GHz 1 Hz to 10 MHz in 1/2/3/5 sequence < –105 dBc (1 Hz), –108 dBc (1 Hz) (typ.)
FPL1003 5 kHz to 3 GHz 1 Hz to 10 MHz in 1/2/3/5 sequence < –105 dBc (1 Hz), –108 dBc (1 Hz) (typ.)

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Power cable
  • Quick start guide

Product Core & Specifications

Specification Value
Frequency
Frequency range 5 kHz to 7.5 GHz
Frequency resolution 0.01 Hz
Reference frequency aging per year (standard) 1 · 10–6
Temperature drift, 0 °C to +50 °C (standard) 1 · 10–6
Achievable initial calibration accuracy (standard) 5 · 10–7
Marker resolution 0.01 Hz
Number of sweep (trace) points, default 1001
Number of sweep (trace) points, range 101 to 100001
Frequency counter resolution 1 Hz
Display range for frequency axis 0 Hz, 10 Hz to max. frequency
Spectral Purity (SSB Phase Noise, f = 1000 MHz)
Carrier offset 100 Hz –88 dBc (1 Hz) (nom.)
1 kHz < –99 dBc (1 Hz)
10 kHz < –105 dBc (1 Hz), –108 dBc (1 Hz) (typ.)
100 kHz < –110 dBc (1 Hz), –115 dBc (1 Hz) (typ.)
1 MHz < –130 dBc (1 Hz), –135 dBc (1 Hz) (typ.)
10 MHz –152 dBc (1 Hz) (nom.)
Sweep Time
Range, span = 0 Hz 1 µs to 8000 s
span ≥ 10 Hz, RBW ≥ 100 kHz 1 ms to 8000 s
span ≥ 10 Hz, RBW < 100 kHz 75 µs to 8000 s
Sweep time accuracy, span = 0 Hz 0.1 % (nom.)
Sweep time accuracy, span ≥ 10 Hz, RBW ≥ 100 kHz 3 % (nom.)
Resolution Bandwidths
Resolution bandwidths (–3 dB), sweep filters 100 kHz to 10 MHz in 1/2/3/5 sequence
FFT filters 1 Hz to 50 kHz in 1/2/3/5 sequence
Bandwidth uncertainty < 3 % (nom.)
Shape factor 60 dB:3 dB < 5 (nom.)
Channel filter bandwidth uncertainty < 2 % (nom.)
Channel filter shape factor 60 dB:3 dB < 2 (nom.)
EMI filters (with R&S®FPL1-K54), bandwidths (–6 dB) 10/100/200 Hz; 1/9/10/100/120 kHz; 1 MHz
Video bandwidths 1 Hz to 10 MHz in 1/2/3/5 sequence
Signal analysis bandwidth (equalized), standard 10 MHz (nom.)
Signal analysis bandwidth (equalized), with R&S®FPL1-B40 40 MHz (nom.)
Level
Display range displayed noise floor up to +30 dBm
Maximum input level, DC voltage 50 V
Maximum CW RF power, RF attenuation 0 dB, preamplifier off 20 dBm (= 0.1 W)
Maximum CW RF power, RF attenuation ≥ 10 dB, preamplifier off 30 dBm (= 1 W)
Maximum pulse voltage, RF attenuation ≥ 10 dB 150 V
Maximum pulse energy, RF attenuation ≥ 10 dB, 10 µs 1 mWs
1 dB compression of input mixer (two tone) +7 dBm (nom.)
TOI, 10 MHz ≤ fin < 300 MHz > 13 dBm, 16 dBm (typ.)
TOI, 300 MHz ≤ fin < 3 GHz > 17 dBm, 20 dBm (typ.)
TOI, 3 GHz ≤ fin ≤ 7.5 GHz > 15 dBm, 18 dBm (typ.)
DANL (RF preamplifier off), 5 kHz ≤ f < 100 kHz –143 dBm (typ.)
100 kHz ≤ f < 5 MHz < –140 dBm, –143 dBm (typ.)
5 MHz ≤ f < 3 GHz < –149 dBm, –152 dBm (typ.)
3 GHz ≤ f < 5 GHz < –143 dBm, –146 dBm (typ.)
5 GHz ≤ f ≤ 7.5 GHz < –140 dBm, –143 dBm (typ.)
Number of traces 6
Trace detector max. peak, min. peak, auto peak (normal), sample, RMS, average
Units of level axis dBm, dBµV, dBmV, dBµA, dBpW, V, A, W
Absolute level uncertainty at 50 MHz, +20 °C to +30 °C < 0.3 dB (σ = 0.1 dB)
Total measurement uncertainty, 1 MHz ≤ f < 3 GHz 0.5 dB
Total measurement uncertainty, 3 GHz ≤ f < 7.5 GHz 0.8 dB
Measurement Speed
Local measurement and display update rate 1 ms (1000/s) (nom.)
Maximum sweep rate, remote operation 0.9 ms (1100/s) (nom.)
Remote measurement and LAN transfer 3.2 ms (357/s) (nom.)
Marker peak search 1.9 ms (nom.)
Trigger Functions
Trigger source free run, video, external, IF power, I/Q power
Trigger offset, span ≥ 10 Hz 0 s to 20 s
IF power trigger sensitivity, min. signal power –60 dBm + RF attenuation – RF preamplifier gain
IF power trigger sensitivity, max. signal power –15 dBm + RF attenuation – RF preamplifier gain
Gate length 10 ns to 20 s, min. resolution 10 ns
I/Q Data
Interface GPIB or LAN interface
Memory length max. 25 Msample I and Q
Word length of I/Q samples 14 bit
Sampling rate, standard 100 Hz to 16 MHz
Sampling rate, with R&S®FPL1-B40 100 Hz to 100 MHz
Maximum signal analysis bandwidth (equalized), standard 12.8 MHz
Maximum signal analysis bandwidth (equalized), with R&S®FPL1-B40 40 MHz
Inputs and Outputs
RF input impedance 50 Ω
RF input connector N female
VSWR (RF attenuation ≥ 10 dB), 10 MHz ≤ f < 3 GHz < 1.5 (nom.)
VSWR, 3 GHz ≤ f < 7.5 GHz < 2 (nom.)
Setting range of attenuator, standard 0 dB to 45 dB, in 5 dB steps
USB interface 4 ports, type A plug, version 2.0
Reference output connector BNC female
Reference input frequency range 10 MHz ± 5 ppm
External trigger/gate input BNC female, 0.5 V to 3.5 V, 10 kΩ
Important: Maximum input levels: 50 V DC; 30 dBm (1 W) CW RF power at RF attenuation >= 10 dB, or 20 dBm (0.1 W) at 0 dB RF attenuation.
Important: Internal lithium-ion battery packs (R&S®FPL1-B31 / R&S®FPL1-Z4) should be stored in an environment with low humidity, free from corrosive gas, at a recommended temperature range below +21 °C. Extended exposure to temperatures above +45 °C could degrade battery performance and life.
Recommended pairing: the optional noise figure and gain measurement application (R&S FPL1-K30) works with the R&S FS-SNS18 or FS-SNS26 smart noise sources listed among the recommended extras.

About this New unit

This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Rohde & Schwarz FPL1007 7.5 GHz Signal and Spectrum Analyzer

Item no : 29214918466
sold recently : Login >>
US$ 10507.50
Pay in 4 interest-free payments of $2626.88 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 26 - Jul 1

Enjoy 20% off shipping

US$ 10507.50

1-11

US$ 9456.75

12-35

US$ 7355.25

36-59

US$ 6304.50

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches