Keysight N1914A Dual-Channel EPM Series Power MeterKeysight N1914A Dual Channel EPM Series Power Meter Key Features At A Glance Single channel (N1913A) or dual channel (N1914A); expandable to four channels via optional USB sensor ports Frequency coverage 9 kHz to 110 GHz and power range 70 to +44 dBm (100 pW to 25 W), sensor dependent Measurement speed up to 400 readings sec with Keysight E Series power sensors Meter absolute accuracy 0. 02 dB 0. 5% (add sensor linearity for overall system accuracy)
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Keysight N1914A Dual-Channel EPM Series Power Meter

Key Features At A Glance

  • Single-channel (N1913A) or dual-channel (N1914A); expandable to four channels via optional USB sensor ports
  • Frequency coverage 9 kHz to 110 GHz and power range –70 to +44 dBm (100 pW to 25 W), sensor dependent
  • Measurement speed up to 400 readings/sec with Keysight E-Series power sensors
  • Meter absolute accuracy ±0.02 dB / ±0.5% (add sensor linearity for overall system accuracy)
  • Industry's first high-resolution color LCD readout in an average power meter
  • GPIB, USB 2.0, and 10/100BaseT LAN/LXI-C interfaces (IEEE 488.2, SCPI) for automated test systems
  • Optional 43x code compatibility to replace 436A, 437B, and 438A power meters; BenchVue BV0007B license included
  • Optional external trigger in/out for automated power and frequency sweep measurements
  • Optional battery operation with single-button battery check and a replaceable spare battery pack

The Keysight N1913A and N1914A are EPM Series power meters built for RF average power measurements. The N1913A is a single-channel average power meter and the N1914A is a dual-channel average power meter. Both are positioned as versatile, user-friendly replacements for the discontinued E4418B/19B EPM Series, and the power range available on any given measurement depends on the connected power sensor.

These meters support the full set of measurement scenarios laid out in the compatible-sensor table: continuous-wave (CW) signals for metrology-lab and mobile-radio work, pulsed and averaged signals for radar and navigation, and modulated signals across wireless standards including GSM, EDGE, GPRS, cdma2000, cdmaONE, iDEN, 3G, HSPA and LTE mobile-phone formats, 802.11a/b/g/n WLAN, Bluetooth, RFID, ZigBee, WiMAX and WiBro. The specific signal types each sensor class supports vary, with several wireless-standard measurements available in average-only mode.

ValueTronics has specialized in new and used test-and-measurement equipment since 1992, operating from a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, where we stock and hold our own inventory.

Brand Heritage

Keysight Technologies traces its instrument heritage to Hewlett-Packard, whose test-and-measurement business was spun out as Agilent Technologies in 1999 and then established as Keysight Technologies in 2014. Much of the EPM Series and its compatible sensor line carries this lineage forward.

Compare Other Models in This Series

The EPM Series spans two power-meter models that share the same measurement architecture, accuracy, color display, and remote-interface set, differing primarily in channel count. The N1913A is a single-channel average power meter and the N1914A is a dual-channel average power meter.

Both models accept the full range of compatible Keysight power sensors — 8480 Series, E4410 and E9300 E-Series, N8480 Series, U2000 and U8480A USB sensors, and U2040/50/60 X-Series — with the usable frequency and power range set by the connected sensor.

Each new model below is its own dedicated product page with condition-matched pricing. Select the model that fits your channel-count and code-compatibility requirements, and review that page's specifications and availability.

The N1913A is backward compatible with the 436A and 437B power meters via the optional 43x code-compatibility option (N1913A-200, or N6901A-1FP as a post-purchase upgrade), making it a direct programmatic replacement in existing single-channel test systems.

The core difference between the models is channels: the N1913A measures a single channel while the N1914A measures two channels simultaneously and can display any two of A, B, A/B, B/A, A-B, B-A and relative. With the optional USB ports, both can expand to four channels (C and D).

Measurement speed and code compatibility also differ. In fast mode with E-Series sensors the N1913A reaches 400 readings/second, while the N1914A reaches a typical 200 readings/second with both channels in fast mode. For legacy code compatibility, the N1913A maps to the 436A and 437B and the N1914A maps to the 438A. See the comparison table for the per-model details.

Model Channels Code Compatibility Max Measurement Speed
N1914A 2 438A 200 readings/sec (both channels FAST)
N1913A 1 436A / 437B 400 readings/sec
N1913A 1 436A / 437B 400 readings/sec

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Power cord
  • Power sensor cable, 1.5 m (5 ft) (two per N1914A)
  • USB cable Type A to Mini-B, 6 ft
  • BenchVue BV0007B Power Meter/Sensor Control and Analysis app license (included)
Replaces: per the manufacturer, this model replaces E4418B, E4419B.

Product Core & Specifications

Specification Value
Performance Characteristics
Compatible power sensors Keysight 8480 Series; Keysight E9300 E-Series; Keysight E4410 E-Series; Keysight N8480 Series; Keysight E8486A, V8486A, W8486A; Keysight U2000 Series; Keysight U8480A Series; Keysight U2040/50/60 X-Series (except U2049XA & U2042/44/60 X-Series in Average mode only)
Frequency range 9 kHz to 110 GHz, sensor dependent
Power range –70 to +44 dBm (100 pW to 25 W), sensor dependent
Single sensor dynamic range 90 dB maximum (Keysight E-Series power sensors); 50 dB maximum (Keysight 8480 Series power sensors); 55 dB maximum (Keysight N8480 Series power sensors); 80 dB maximum (Keysight U2000 Series USB power sensors); 55 dB maximum (Keysight U8480A Series USB power sensors); 96 dB maximum (Keysight U2040/50/60 X-Series, except U2049XA & U2042/44/60 X-Series in Average mode only)
Display units Absolute: Watts or dBm. Relative: Percent or dB
Display resolution Selectable resolution of 1.0, 0.1, 0.01 and 0.001 dB in logarithmic mode, or 1, 2, 3 and 4 significant digits in linear mode
Default resolution dB in logarithmic mode or three digits in linear mode
Accuracy
Absolute accuracy ± 0.02 dB (Logarithmic) or ± 0.5% (Linear). Please add the corresponding power sensor linearity percentage to assess the overall system accuracy.
Relative accuracy ± 0.04 dB (Logarithmic) or ± 1.0% (Linear). Please add the corresponding power sensor linearity percentage to assess the overall system accuracy.
Zero set (digital stability of zero) 0.0000175% (meter only). Power sensor dependent (refer Table 1); applies when zeroing is performed with sensor input disconnected from the POWER REF.
Zero drift of sensors Sensor dependent; the change in the power meter indication over a long time (within one hour) at a constant temperature after a 24-hour warm-up of the power meter. Refer to Table 3.
Measurement noise Sensor dependent (refer to Tables 1 and 2).
Effects of averaging on noise Averaging over 1 to 1024 readings is available for reducing noise.
1 mW Power Reference
Power output 1.00 mW (0.0 dBm). Factory set to ± 0.4 % traceable to the National Physical Laboratories (NPL), UK
Accuracy (for two years) ± 0.4% (25 ± 10 ºC); ± 1.2% (0 to 55 ºC)
Frequency 50 MHz nominal
SWR 1.05 (typical), 1.08 (0 to 55 ºC)
Connector type Type-N (f), 50 Ω
Measurement Speed (remote interface)
N1913A — Normal 20 readings/second
N1913A — x2 40 readings/second
N1913A — Fast 400 readings/second, for Keysight E-Series power sensors only
N1914A — both channels in FAST mode Typical maximum measurement speed 200 readings/second (Fast mode for Keysight E-Series power sensors only)
FAST mode settling time (E-Series, free run trigger, –50 dBm to +17 dBm, 10 dB decreasing power step) N1913A: 10 ms; N1914A: 20 ms
Power Meter Functions
Zero Zeros the meter. (Power reference calibrator is switched off during zeroing.)
Cal Calibrates the meter using internal (power reference calibrator) or external source. Reference cal factor settable from 1% to 150%, in 0.1% increments.
Frequency Entered frequency range is used to interpolate the calibration factors table. Frequency range from 1 kHz to 999.9 GHz. Also settable in 1 kHz steps.
Cal factor Sets the calibration factor for the meter. Range: 1% to 150%, in 0.1% increments.
Relative Displays all successive measurements relative to the last displayed value
Offset Allows power measurements to be offset by –100 dB to +100 dB, settable in 0.001 dB increments, to compensate for external loss or gain
Save/recall Store up to 10 instrument states via the save/recall menu
dBm/W Selectable units of either Watts or dBm in absolute power; or percent or dB for relative measurements
Filter (averaging) Selectable from 1 to 1024. Auto-averaging provides automatic noise compensation.
Duty cycle Duty cycle values between 0.001% to 99.999%, in 0.001% increments, can be entered to display a peak power representation of measured power (peak power = measured power / duty cycle).
Sensor cal tables Selects cal factor versus frequency tables corresponding to specified sensors
Limits High and low limits can be set in the range –150.000 to +230.000 dBm, in 0.001 dBm increments
Preset default values dBm mode, rel off, power reference off, duty cycle off, offset off, frequency 50 MHz, AUTO average, free run, AUTO range (for E-Series sensors and N8480 Series)
Display Color display with selectable single and split screen formats. A quasi-analog display is available for peaking measurements. The dual channel power meter can simultaneously display any two configurations of A, B, A/B, B/A, A-B, B-A and relative. With the optional USB ports, additional dual channel (C & D) adds up to a total of 4-channel measurement display.
General Specifications
Dimensions (excludes front and rear protrusions) 212.6 mm W x 88.5 mm H x 348.3 mm D (8.5 in x 3.5 in x 13.7 in)
Net weight N1913A: 3.6 kg (8.0 lb); N1914A: 3.7 kg (8.2 lb)
Shipping weight N1913A: 8.2 kg (18.1 lb); N1914A: 8.2 kg (18.3 lb)
Rear Panel Connectors
Recorder outputs Analog 0 to 1 volt, 1 kΩ output impedance, BNC connector. N1914A recorder outputs are dedicated to channel A and channel B.
GPIB, USB 2.0 and 10/100BaseT LAN Interfaces to allow communication with an external controller
Trigger Input (optional) TTL compatible logic levels, BNC connector: High: > 2.4 V; Low: < 0.7 V
Trigger Output (optional) TTL compatible logic levels, BNC connector: High: > 2.4 V; Low: < 0.7 V
Ground Binding post, accepts 4 mm plug or bare wire connection
USB Host (options) USB ports which connect to USB power sensors
VGA Out (options) Standard 15-pin VGA connector, allows connection of external VGA monitor
Line Power
Input voltage range 90 to 264 VAC, automatic selection
Input frequency range 47 to 63 Hz and 400 Hz at 110 Vac
Power requirement 75 VA (50 Watts)
Environmental Characteristics
Electromagnetic compatibility Complies with the essential requirements of EMC Directive (2004/108/EC): IEC61326-1:2005 / EN61326-1:2006; CISPR11:2003 / EN55011:2007 (Group 1, Class A); Canada: ICES/NMB-001:2004; Australia/New Zealand: AS/NZS CISPR 11:2004
Product safety IEC/EN 61010-1; CAN/CSA-C22.2 No.61010-1-04; ANSI/UL61010-1:2004
Low Voltage Directive 2006/95/EC
Operating temperature 0 to 55 °C
Maximum humidity 95% at 40 °C (non-condensing)
Minimum humidity 15% at 40 °C (non-condensing)
Maximum altitude 4,600 meters (15,000 feet)
Non-operating storage temperature –40 to +70 °C
Non-operating maximum humidity 90% at 65 °C (non-condensing)
Battery Option (characteristic, at 25 °C)
Charge time Approximately 2.5 hours to charge fully from an empty state; power meter is operational whilst charging
Battery type Lithium-ion (Li-ion)
Battery storage temperature –20 °C to 60 °C, ≤80 % RH
Remote Programming
GPIB compatibility SH1, AH1, T6, TE0, L4, LE0, SR1, RL1, PP1, DC1, DT1, C0
Important: Fast mode (400 readings/sec) is available with Keysight E-Series power sensors only.
Important: A compatible power sensor is required to make measurements and is not included with the power meter; the measurable frequency and power range depend on the connected sensor. The N1913A/N1914A support all average power sensors, including the 8480 Series (including discontinued models), N8480 Series, E-Series (E4410/E9300), and supported U2000/U8480A/U2040-50-60 X-Series USB sensors. Order the appropriate power sensor separately.
Important: 43X code compatibility is available only with option N191xA-200 at time of purchase (N1913A is backward compatible with 436A and 437B; N1914A is compatible with 438A), or as a post-purchase upgrade (N6901A-1FP for N1913A, N6902A-1FP for N1914A).
Important: Option 101 (front-panel calibrator and sensors) cannot be ordered together with any of the B0x or C0x options.
Important: Option 201 requires Option B01 (without battery), which is mandatory for Option 201.

About this New unit

This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Keysight N1914A Dual-Channel EPM Series Power Meter

Item no : 75540243887
sold recently : Login >>
US$ 5429.00
Pay in 4 interest-free payments of $1357.25 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 26 - Jul 1

Enjoy 20% off shipping

US$ 5429.00

1-11

US$ 4886.10

12-35

US$ 3800.30

36-59

US$ 3257.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches