Shopping security
The Keysight E36441A is a four-output autoranging bench DC power supply that delivers 400 W of total power, with each of its four outputs rated at 160 W, 32 V, and 10 A. It pairs accurate voltage and current programming and readback with layered device protection, so an engineer can power a device under test with confidence.
The instrument is designed to address applications that test multiple devices or test points simultaneously. A single E36441A can power several analog or digital circuits at once, saving bench space compared with operating multiple single-output supplies. Its tracking mode varies four symmetrical voltages together, a convenience when supplying the balanced positive and negative rails required by operational amplifiers and similar circuits.
ValueTronics stocks and holds its own inventory in a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, and has specialized in new and used test and measurement equipment since 1992.
Keysight Technologies traces its test and measurement heritage to Hewlett-Packard, whose instrument business was spun off as Agilent Technologies in 1999. Agilent's electronic measurement business then became the independent Keysight Technologies in 2014.
| Specification | Value |
|---|---|
| Performance Specifications | |
| Power output | 400 W |
| DC output ratings (0 to 40 ºC) – Power per channel (Ch 1–4) | 160 W |
| DC output ratings (0 to 40 ºC) – Voltage per channel (Ch 1–4) | 0 to 32 V |
| DC output ratings (0 to 40 ºC) – Current per channel (Ch 1–4) | 0 to 10 A |
| Auto Series mode voltage (with E364SNP kit) | 128 V |
| Auto Parallel mode current (with E364SNP kit) | 40 A |
| Load Regulation (0 to 40 ºC), ± (% of output + offset) | |
| Voltage | < 0.01% + 2 mV |
| Current | < 0.1% + 5 mA |
| Line Regulation (0 to 40 ºC), ± (% of output + offset) | |
| Voltage | < 0.01% + 2 mV |
| Current | < 0.1% + 5 mA |
| Output Ripple and Noise | |
| Normal mode voltage, Vpp (20 Hz to 20 MHz) | < 10 mV |
| Normal mode voltage, Vrms (20 Hz to 1 MHz) | < 1 mV |
| Accuracy 12 Months (23 ºC ± 5 ºC), ± (% of output + offset) | |
| Programming accuracy – Voltage | 0.06% + 6 mV |
| Programming accuracy – Current | 0.1% + 6 mA |
| Readback accuracy – Voltage | 0.05% + 5.5 mV |
| Readback accuracy – Current | 0.1% + 3.5 mA |
| Load Transient Recovery Time (approximately 23 ºC ± 5 ºC) | |
| Voltage settling band | 15 mV |
| Time | < 55 uS |
| Typical Characteristics | |
| Programming resolution – Voltage | 1 mV |
| Programming resolution – Current | 1 mA |
| Readback resolution – Voltage | 0.5 mV |
| Readback resolution – Current | 1 mA |
| Programming front panel – Voltage | 1 mV |
| Programming front panel – Current | 1 mA |
| Readback front panel – Voltage | 1 mV |
| Readback front panel – Current | 1 mA |
| Output ripple and noise (20 Hz to 10 MHz) – Normal mode current | < 4 mArms |
| Overvoltage protection (OVP) programming accuracy, ± (% of output + offset) | 0.2% + 0.4 V |
| Activation time – Overvoltage (OVP) | < 5 ms |
| Activation time – Overcurrent (OCP) | < 5 ms |
| Command processing time | < 10 ms |
| Programming temperature coefficient per ºC – Voltage | 0.01% + 0.6 mV |
| Programming temperature coefficient per ºC – Current | 0.01% + 0.2 mA |
| Readback temperature coefficient per ºC – Voltage | 0.01% + 0.04 mV |
| Readback temperature coefficient per ºC – Current | 0.01% + 0.2 mA |
| Remote sense (maximum voltage in load lead) | 0.7 V |
| Up/Down programming settling time (within 1%) – Up full load | 80 ms |
| Up/Down programming settling time (within 1%) – Up no load | 80 ms |
| Up/Down programming settling time (within 1%) – Down full load | 60 ms |
| Up/Down programming settling time (within 1%) – Down no load | 500 ms |
| Connectivity | USB and LAN |
| LXI compliance | Class C |
| USB 2.0 | Requires Keysight IO library version 17.2.208 and up |
| 10 Mb/s LAN, 100 Mb/s LAN | Requires Keysight IO library version 17.2.208 and up |
| Digital Control Characteristics | |
| Maximum voltage ratings | + 16.5 VDC / -5 VDC between pins (pin 4 internally connected to chassis ground) |
| Pin 1 and 2 as fault output | Maximum low-level output voltage = 0.5 V @ 4 mA; Maximum low-level sink current = 4 mA; Typical high-level leakage current = 1 mA @ 16.5 VDC |
| Pin 1 – 3 as digital/trigger outputs (pin 4 as common) | Maximum low-level output voltage = 0.5 V @ 4 mA; 1 V @ 50 mA; 1.75 V @ 100 mA; Maximum low-level sink current = 100 mA; Typical high-level leakage current = 0.8 mA @ 16.5 VDC |
| Pin 1 – 3 as digital/trigger inputs and pin 3 as inhibit (pin 4 as common) | Maximum low-level input voltage = 0.8 V; Minimum high-level input voltage = 2 V; Typical low-level leakage current = 2 mA @ 0 V (internal 2.2k pull-up); Typical high-level leakage current = 0.12 mA @ 16.5 V |
| Data logger function | Measurement interval from 200 ms to 60 sec with a maximum duration of 20,000 hours |
| Voltage slew rate | Control from 50 ms to 15,000 sec, from 0 V to max V transition |
| Environmental Conditions | |
| Operating environment | Indoor use, installation category II (for AC input), pollution degree 2 |
| Operating temperature range | 0 ºC to 40 ºC |
| Storage temperature range | -20 ºC to 70 ºC |
| Relative humidity | 80% RH at temperatures up to 40 ºC, non-condensing |
| Altitude | Up to 2000 meters |
| Electromagnetic compatibility | Compliant with EMC directive (2014/30/EU); IEC 61326-1:2012/EN 61326-1:2013 Group 1 class A; Canada: ICES-001:2004; Australia/New Zealand: AS/NZS; South Korea KC mark |
| Safety | UL 61010-1 3rd editions; CAN/CSA-C22.2 No. 61010-1-12; IEC 61010-1:2010 3rd edition; Sound pressure Lp < 70db(A) at operator position; Normal operation according to EN 27779 |
| AC input | ~ 100 VAC to 240 VAC (±10%), 50/60 Hz, < 900 VA |
| Net weight | 11 kg |
| Bench dimensions, mm (H x W x D) | 165 x 314 x 281 |
Important: The optional E364SNP Series and Parallel Kit does not include four-wire remote sense.
Important: Accuracy specifications are after 1 hour warm-up with no load and calibrated at 23 ºC ± 5 ºC.
Important: Specification may degrade when the unit is subjected to an RF field ≥ 3 V/meter.
Recommended pairing: add the E364SNP Series and Parallel Kit to combine all four channels into a single output of up to 128 V or 40 A for higher-voltage or higher-current needs.
This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Ships within 48 hours · Estimated delivery Jun 26 - Jul 1
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order